Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Orofac Orthop ; 2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36129485

RESUMO

PURPOSE: The use non-invasive or minimally invasive methods to accelerate orthodontic tooth movements (OTM) is desirable. In this regard, low-level laser therapy (LLLT, photobiomodulation) and piezocision are suggested. However, because the efficacies of these methods remain controversial/inconclusive, we investigated and compared these two methods. METHODS: Sixty-four quadrants in 32 patients were randomized into three parallel intervention groups of 22, 22, and 20 (6 parallel arms, n = 64 treatment/control sides). Bilateral first premolars were extracted and canine retraction commenced. In each group, one side of the mouth was randomly selected as control, while the other side underwent each of three interventions: LLLT (940 nm, 8 J, 0.5 W, 16 s, 12 sites), piezocision, and "LLLT + piezocision". At the 3rd, 6th, and 9th follow-up weeks, canine retraction and anchorage loss were measured. Data were analyzed statistically (α = 0.05). RESULTS: After 9 weeks, LLLT, piezocision, and LLLT + piezocision improved canine retraction by 0.51, 1.14, and 1.93 mm, respectively. LLLT accelerated canine retraction (compared to control) by 1.6-, 1.4-, and 1.2-fold in the 3rd, 6th, and 9th week, respectively. These statistics were 2.1-, 1.7-, and 1.5-fold for piezocision and 2.7-, 2.1-, and 1.8-fold for LLLT + piezocision. Compared to controls, each intervention showed significant retraction acceleration (p < 0.05). The effect of LLLT + piezocision was greater than that of isolated piezocision (p < 0.05), which itself was greater than that for isolated LLLT (p < 0.05). CONCLUSION: All three methods accelerated OTM, with the combination of LLLT + piezocision producing the strongest and LLLT producing the weakest acceleration.

2.
Front Dent ; 18: 30, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35965692

RESUMO

Impaction of the anterior teeth, which is less frequent in central incisors, can cause serious esthetic and subsequent psychological problems for patients during the mixed dentition period. Traumatic injury to deciduous teeth is the most common etiologic factor. Thus, treatment of maxillary incisor impaction is highly important. Nowadays, application of laser has been suggested in orthodontics and pediatric dentistry for different treatments, such as surgical exposure of impacted teeth and application of low-level laser therapy (LLLT) for acceleration of orthodontic tooth movement. In this paper, the authors present treatment of an impacted and dilacerated maxillary central incisor with laser application for its surgical exposure and LLLT for acceleration of its orthodontic traction and eruption.

3.
J Lasers Med Sci ; 11(4): 405-410, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33425290

RESUMO

Introduction: This study aimed to assess the effect of photodynamic therapy (PDT) and chitosan separately and in combination on Streptococcus mutans. Methods: This in vitro experimental study evaluated 216 microbial samples in 6 groups. First, 5 µL of 0.5 McFarland standard suspension of S. mutans was added to each well of an ELISA microplate; 100 µL of Mueller Hinton broth was also added to each well; 180 wells contained S. mutans suspension while 36 wells were devoid of bacteria. Group 1 served as the negative control and had no bacteria. Group 2 served as the positive control and S. mutans in the positive control wells did not undergo any intervention. In groups 3 and 4, PDT with a 50 mW low-level laser was performed for 30 and 40 seconds respectively. In group 5, 3 mg/mL of chitosan (100 µL) was used. In group 6, 3 mg/mL (100 µL) of chitosan was used in combination with PDT (50 mW laser for 30 seconds). The laser was irradiated under aseptic conditions at a 660 nm wavelength with 50 mW power. Data were analyzed using one-way ANOVA and Tukey's test. Results: PDT combined with chitosan showed maximum bactericidal effect followed by PDT for 40 seconds and chitosan groups (P < 0.05). PDT for 30 seconds showed a minimum bactericidal effect (P < 0.05). All pairwise comparisons revealed significant differences (P < 0.001). Conclusion: Chitosan and PDT alone can be used to decrease the S. mutans count. However, their combined use has a greater bactericidal effect on S. mutans .

4.
Laser Ther ; 28(3): 193-198, 2019 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-32009733

RESUMO

BACKGROUND AND AIMS: Dentin hypersensitivity is a frequent oral condition among patients suffering from gingival recession. Recent studies have suggested that photobiomodulation has the potential to reduce inflammation and relieve pain. The present study aims to assess the effectiveness of a new design of photobiomodulation toothbrush with specific irradiation parameters as a homecare device in treating dentin hypersensitivity and to compare its therapeutic effect with that of fluoride varnish. MATERIALS AND METHODS: Thirty patients with gingival recession and dentin hypersensitivity were selected and randomly assigned to three groups of equal size: fluoride varnish, photobiomodulation, and the combination. Dentin pain and hypersensitivity were measured using visual analog scale (VAS) by two distinct tests: the contact test with a periodontal probe and the air blast test on the areas of gingival recession and denuded root; once at baseline and again one month after the initial application of treatments. Laser irradiation was carried out at the wavelength of 660 nm in CW with an output power of 40 mW for 30 seconds per spot (1.2 J per spot, 6 J/cm2 energy density, and 200 mW/cm2 power density), perpendicularly to denuded root surfaces in non-contact mode. RESULTS: A significant reduction in dentin pain and hypersensitivity was observed in all three groups. However, the reduction was significantly greater in the combination group. CONCLUSION: At-home treatment of dentin hypersensitivity with photobiomodulation toothbrush is a convenient, safe, and effective method for the management of dentin hypersensitivity.

5.
Clin Cosmet Investig Dent ; 4: 29-35, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23674923

RESUMO

BACKGROUND: Mechanical torque devices (MTDs) are one of the most commonly recommended devices used to deliver optimal torque to the screw of dental implants. Recently, high variability has been reported about the accuracy of spring-style mechanical torque devices (S-S MTDs). Joint stability and survival rate of fixed implant supported prosthesis depends on the accuracy of these devices. Currently, there is limited information on the steam sterilization influence on the accuracy of MTDs. The purpose of this study was to assess the effect of steam sterilization on the accuracy (±10% of the target torque) of spring-style mechanical torque devices for dental implants. MATERIALS AND METHODS: Fifteen new S-S MTDs and their appropriate drivers from three different manufacturers (Nobel Biocare, Straumann [ITI], and Biomet 3i [3i]) were selected. Peak torque of devices (5 in each subgroup) was measured before and after autoclaving using a Tohnichi torque gauge. Descriptive statistical analysis was used and a repeated-measures ANOVA with type of device as a between-subject comparison was performed to assess the difference in accuracy among the three groups of spring-style mechanical torque devices after sterilization. A Bonferroni post hoc test was used to assess pairwise comparisons. RESULTS: Before steam sterilization, all the tested devices stayed within 10% of their target values. After 100 sterilization cycles, results didn't show any significant difference between raw and absolute error values in the Nobel Biocare and ITI devices; however the results demonstrated an increase of error values in the 3i group (P < 0.05). Raw error values increased with a predictable pattern in 3i devices and showed more than a 10% difference from target torque values (maximum difference of 14% from target torque was seen in 17% of peak torque measurements). CONCLUSION: Within the limitation of this study, steam sterilization did not affect the accuracy (±10% of the target torque) of the Nobel Biocare and ITI MTDs. Raw error values increased with a predictable pattern in 3i devices and showed more than 10% difference from target torque values. Before expanding upon the clinical implications, the controlled and combined effect of aging (frequency of use) and steam sterilization needs more investigation.

6.
Lasers Med Sci ; 25(1): 61-5, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19238504

RESUMO

A growth center of the mandible that contributes to its length and height is the mandibular condyle. Proliferation of prechondroblasts, followed by synthesis of the extracellular matrix and hypertrophy of the cartilage cells, governs the major part of condylar growth. The sample consisted of 54 male rats, weighing between 60 g and 80 g, divided randomly into three groups. Group I was the control group, group II was irradiated bilaterally, and group III was irradiated on the right side. Laser irradiation (lambda = 904 nm, 2000 Hz, pulse length 200 ns and output power 4 mW) was performed, and the procedure was repeated after a 50-day interval. Two months later, the rats were killed. In a single blind manner the lengths of denuded mandibles and the lengths of mandibles on soft tissue were measured. The growth of the mandibles in the unilaterally irradiated group (P < 0.001) and the bilaterally irradiated group (P < 0.05) was significantly more than that in the control group. There was no significant difference between right and left condylar growth in the bilaterally irradiated group (P = 0.3). Soft tissue analysis also verified these results (P < 0.001). Histomorphometric results also revealed a significant difference between laser-irradiated groups and the control group (P < 0.01). We concluded that particular laser irradiation with the chosen parameters can stimulate condylar growth and subsequently cause mandibular advancement. These findings might be clinically relevant, indicating that low level laser irradiation can be used for further improvement of mandibular retrognathism.


Assuntos
Terapia com Luz de Baixa Intensidade/métodos , Côndilo Mandibular/crescimento & desenvolvimento , Côndilo Mandibular/efeitos da radiação , Animais , Condrócitos/citologia , Condrócitos/efeitos da radiação , Humanos , Lasers Semicondutores/uso terapêutico , Masculino , Côndilo Mandibular/citologia , Modelos Animais , Osteoblastos/citologia , Osteoblastos/efeitos da radiação , Ratos , Ratos Wistar , Retrognatismo/patologia , Retrognatismo/terapia , Fatores de Tempo
7.
Lasers Med Sci ; 25(1): 9-15, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18663557

RESUMO

Direct pulp capping (DPC) is coverage of exposed pulp by a biocompatible material after traumatic or carious exposure. The purpose of this procedure is to seal this spot against bacterial leakage, stimulate dentinal barrier formation, and maintain the vitality of the pulp. Several factors contribute to the consequence of this treatment, such as the kind of material used and the procedural technique. The aim of this study was to evaluate histologically the outcome of DPC using three methods. Thirty-six canine teeth of nine cats were selected for this experiment. After the cats had been anesthetized, the teeth were exposed under sterile condition. The teeth were randomly divided into three groups. In group I, the exposed pulp was covered with mineral trioxide aggregate (MTA) alone. In group II, the pulp, after being treated with erbium:yttrium-aluminum-garnet (Er:YAG) laser (energy = 200 mJ, pulse duration = 700 micros, repetition rate = 3 Hz, exposure time = 15 s, no air, no water, beam diameter = 0.6 mm), was covered with MTA. In group III, the pulp was treated with laser and covered with calcium hydroxide [Ca(OH)(2)]. All cavities were filled with amalgam after DPC. After 4 months, the animals were sacrificed and block sections were prepared. The specimens were histologically evaluated. The data were analyzed by Mann-Whitney and chi-square tests. Dentinal barrier had formed in all groups. The laser + MTA group showed little superiority to the other groups in dentinal barrier formation, type and intensity of inflammatory responses, and soft tissue changes, especially necrosis, but these differences were not statistically significant (P > 0.05). We concluded that laser + MTA produced better healing. According to the conditions in this study, Er:YAG laser could be used in direct pulp capping treatment in combination with both common materials.


Assuntos
Capeamento da Polpa Dentária/métodos , Polpa Dentária/patologia , Lasers de Estado Sólido/uso terapêutico , Compostos de Alumínio/administração & dosagem , Animais , Compostos de Cálcio/administração & dosagem , Hidróxido de Cálcio/administração & dosagem , Gatos , Dente Canino/cirurgia , Materiais Dentários , Combinação de Medicamentos , Teste de Materiais , Óxidos/administração & dosagem , Silicatos/administração & dosagem
8.
Lasers Med Sci ; 24(5): 715-20, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19002646

RESUMO

Myofacial pain dysfunction syndrome (MPDS) is the most common reason for pain and limited function of the masticatory system. The effects of low-level lasers (LLLs) for controlling the discomfort of patients are investigated frequently. However, the aim of this study was to evaluate the efficacy of a particular source producing 660 nm and 890 nm wavelengths that was recommended to reduce of the pain in the masticatory muscles. This was a double-blind and placebo-controlled trial. Sixteen MPDS patients were randomly divided into two groups. For the laser group, two diode laser probes (660 nm (nanometers), 6.2 J/cm(2), 6 min, continuous wave, and 890 nm, 1 J/cm(2) (joules per square centimetre), 10 min, 1,500 Hz (Hertz)) were used on the painful muscles. For the control group, the treatment was similar, but the patients were not irradiated. Treatment was given twice a week for 3 weeks. The amount of patient pain was recorded at four time periods (before and immediately after treatment, 1 week after, and on the day of complete pain relief). A visual analog scale (VAS) was selected as the method of pain measurement. Repeated-measures analysis of variance (ANOVA), the t-test and the paired t-test were used to analyze the data. In each group the reduction of pain before and after the treatment was meaningful, but, between the two groups, low-level laser therapy (LLLT) was more effective (P = 0.031) According to this study, this type of LLLT was the effective treatment for pain reduction in MPDS patients.


Assuntos
Terapia com Luz de Baixa Intensidade , Síndrome da Disfunção da Articulação Temporomandibular/radioterapia , Adolescente , Adulto , Método Duplo-Cego , Feminino , Humanos , Terapia com Luz de Baixa Intensidade/métodos , Masculino , Músculos da Mastigação/fisiopatologia , Músculos da Mastigação/efeitos da radiação , Fenômenos Ópticos , Dor/fisiopatologia , Dor/radioterapia , Síndrome da Disfunção da Articulação Temporomandibular/fisiopatologia , Fatores de Tempo , Adulto Jovem
9.
Lasers Med Sci ; 24(3): 365-74, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-18654826

RESUMO

The exact mechanism of the ablation of tooth hard tissue with most common wavelengths, which are 2,940 nm and 2,780 nm, is not yet clear. There are several different theories, but none of them has yet been established. Concepts and methods of looking at these mechanisms have been based on heat formation and transformation, and mathematical calculations evaluating the outcome of ablation, such as looking at the shape of cuts. This study provides a new concept, which is the monitoring of the direct interactions between laser light, water and enamel, with a high-speed camera. For this purpose, both the above-mentioned wavelengths were examined. Bovine anterior teeth were prepared as thin slices. Each imaged slice had a thickness close to that of the beam diameter so that the ablation effect could be shown in two dimensional pictures. The single images were extracted from the video-clips and then were animated. The following steps, explaining the ablation procedures during each pulse, were seen and reported: (1) low-output energy intensity in the first pulses that did not lead to an ablative effect; (2) bubble formation with higher output energy density; (3) the tooth surface during the pulse was covered with the plume of vapour (comparable with a cloud), and the margins of ablation on the tooth were not clear; (4) when the vapour bubble (cloud) was collapsing, an additional ablative process at the surface could be seen.


Assuntos
Lasers de Estado Sólido/uso terapêutico , Terapia com Luz de Baixa Intensidade/métodos , Preparo do Dente/métodos , Animais , Bovinos , Técnicas In Vitro , Fotografia Dentária/instrumentação , Fotografia Dentária/métodos , Preparo do Dente/classificação , Gravação em Vídeo , Água
10.
Lasers Med Sci ; 24(1): 7-12, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18087764

RESUMO

This preliminary study was to investigate in vitro the Er,Cr:YSGG laser ablation capability, both range (enlargement aspects of laser tips corresponded to conventional endodontic files) and quality (removing of smear layer and opening of dentinal tubules) to clean and shape the root canal for final obturation step. The crowns of 15 extracted multi-rooted posterior human teeth were resected, and then 15 canals were prepared by an Er,Cr:YSGG laser up to 1.5 W (actual power output) using the step-back technique, while the other 15 canals (control) were enlarged conventionally by K-flex file. The results revealed that posterior root-canal preparation could be achieved by laser beam transmitted to the canal using endodontic tips. At a chosen significance level of alpha = 1%, the results showed no significant statistical difference between the two groups (P > 0.01). Considering the results of this current study, laser-based root-canal preparation still shows certain limitations, and further improvements are mandatory for higher achievement and better preparation outcomes.


Assuntos
Lasers de Estado Sólido , Preparo de Canal Radicular/métodos , Coroas , Humanos , Técnicas In Vitro , Microscopia Eletrônica de Varredura
11.
Lasers Med Sci ; 23(3): 291-4, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17641927

RESUMO

Dentine hypersensitivity has of long been known to be a common clinical problem in dental practices. Lasers have recently come to play a prominent role in the treatment of this disorder. They might, however, cause dental pulp damage. This study was conducted to evaluate the effect of Nd:yttrium-aluminum-garnet (YAG) laser on partial oxygen saturation of pulpal blood in sensitive anterior teeth. In this clinical trial, 65 hypersensitive teeth were selected and randomly allocated to two groups. The study group involved Nd:YAG laser treatment, while no treatment was employed for the control group. Using a pulse oximetry system, evaluations were preformed of the partial oxygen saturation in the pulpal blood before, immediately after, 1 week after, and 1 month after the treatment. The results were analyzed using the SPSS software and repeated-measures analysis of variance and paired-samples t tests. The mean partial oxygen saturation of the blood was found to be 85.4% in the study group, which was not significantly different from that of the control group. No significant differences were observed in the control group between the means obtained from pretreatment and post-treatment intervals (P > 0.05). The Post-treatment partial oxygen saturation mean rose to 89.3% (P = 0.001) and remained constant throughout the following week after it. However, no significant differences were found between the pretreatment partial oxygen saturation mean and the same measurement 1 month after treatment (P = 0.702). Nd:YAG laser therapy for dentine desensitization of anterior teeth caused no persistent changes in the partial oxygen saturation of pulpal blood. It may, therefore, be concluded that the diffusion of heat induced by the Nd:YAG laser into the pulp within the limit of the desensitization parameters cause no irreversible damages in the dental pulp.


Assuntos
Polpa Dentária/irrigação sanguínea , Sensibilidade da Dentina/terapia , Terapia a Laser , Oxigênio/sangue , Adulto , Análise de Variância , Feminino , Humanos , Masculino , Neodímio , Medição da Dor , Resultado do Tratamento
12.
Lasers Med Sci ; 23(3): 283-7, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17764026

RESUMO

There are several studies done to show the comparability of laser scaling and root planing with routine methods. The most suitable wavelengths for such an application are reported as 2,940 and 2,780 nm. The superficial interactions of the current wavelength with root surface is investigated in this study to compare the crater and crack formation during the procedures between ultrasound and Er,Cr:yttrium-scandium-gallium garnet (YSGG; 2,780 nm) laser-treated teeth. Thirty human teeth with calculus on their root surface, which were extracted because of the severe periodontitis, were selected for this interventional in vitro study. Calculus area were divided into two equal parts: One of them was prepared for Er,Cr:YSGG (Biolase, Waterlase, USA) laser irradiation and the other one for ultrasound treatment (Dentsply cavitron, DENTSPLY International, USA). The Er,Cr:YSGG laser was specified as follows: pulse energy = 50 mJ, power = 1 W, wavelength = 2,780 nm, pulse repetition rate = 20 pulse per seconds, tip length = 6 mm, and tip diameter = 600 microm. Nineteen of the laser samples (95%) and eight of ultrasound ones (40%) out of 20 samples in each group had craters showing a statistical significant difference (p < 0.001). The number and depth of these craters are also evaluated. Thirteen samples of the laser cases (65%) and all samples of the ultrasound group showed cracks with significant differences (p = 0.008). In addition, the number and width of cracks in both groups are reported. As a general conclusion, the laser-treated samples show more craters but less cracks.


Assuntos
Cálculos Dentários/radioterapia , Raspagem Dentária/instrumentação , Aplainamento Radicular/instrumentação , Raiz Dentária/efeitos da radiação , Terapia por Ultrassom/instrumentação , Distribuição de Qui-Quadrado , Cromo , Érbio , Humanos , Microscopia Eletrônica de Varredura , Estatísticas não Paramétricas , Propriedades de Superfície , Raiz Dentária/ultraestrutura
13.
Lasers Med Sci ; 23(3): 331-5, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17786499

RESUMO

Biostimulatory effects of laser irradiation on cell proliferation and wound healing has been reported. However, little is known about the molecular basis of the mechanism. Interleukin 1beta (IL-1beta), tumor necrotic factor-alpha (TNF-alpha), and interferon-gamma (IFN-gamma) play an important role in inflammation, while platelet-derived growth factor (PDGF), transforming growth factor-beta (TGF-beta) and blood-derived fibroblast growth factor (bFGF) are the most important growth factors of periodontal tissues. The aim of this study was to investigate the effect of low-level He-Ne laser on the gene expression of these mediators in rats' gingiva and mucosal tissues. Twenty male Wistar rats were randomly assigned into four groups (A(24), A(48), B(24), B(48)) in which A(24) and A(48) were cases and B(24), B(48) were controls. An incision was made on gingiva and mucosa of the labial surface of the rats' mandibular incisors. Group A(24) was irradiated twice with 24 hours interval, while the inflamed tissues of group A(48) was irradiated three times with continuous He-Ne laser (632.8 nm) at a dose of 7.5 J/cm2 for 300 s. An energy of 5.1 J was given to the 68 mm(2) irradiation zone. Rats were killed 30 min after the last irradiation of case and control groups, then excisional biopsy was performed. Gene expression of the cytokines was measured using reverse transcriptase-polymerase chain reaction (RT-PCR) technique. Results were analyzed with Kruskal-Wallis and Mann-Whitney U tests. The gene expression of IL-1beta and IFN-gamma was significantly inhibited in the test groups (P < 0.05), while the gene expression of PDGF and TGF-beta were significantly increased (P < 0.05). The case and control groups did not have a significant difference in the gene expression of TNF-alpha and bFGF (P > 0.05). These findings suggest that low-level He-Ne laser irradiation decreases the amount of inflammation and accelerates the wound healing process by changing the expression of genes responsible for the production of inflammatory cytokines.


Assuntos
Expressão Gênica/efeitos da radiação , Gengiva/efeitos da radiação , Terapia com Luz de Baixa Intensidade/instrumentação , Animais , Fator 2 de Crescimento de Fibroblastos/genética , Fator 2 de Crescimento de Fibroblastos/metabolismo , Hélio , Interferon gama/genética , Interferon gama/metabolismo , Interleucina-1beta/genética , Interleucina-1beta/metabolismo , Masculino , Neônio , Fator de Crescimento Derivado de Plaquetas/genética , Fator de Crescimento Derivado de Plaquetas/metabolismo , Distribuição Aleatória , Ratos , Ratos Wistar , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Estatísticas não Paramétricas , Fator de Crescimento Transformador beta/genética , Fator de Crescimento Transformador beta/metabolismo , Fator de Necrose Tumoral alfa/genética , Fator de Necrose Tumoral alfa/metabolismo
14.
Lasers Med Sci ; 23(4): 451-7, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17952484

RESUMO

Different ideas have been presented to describe the mechanism of augmented laser ablation of dental enamel with different shapes by adding water to the working environment. In this study, the influence of water-laser interaction on the surface of enamel during ablation was investigated at a wavelength of 2.94 microm with different distances between the laser tip and the enamel surface. A motion-control system was used to produce linear incisions uniformly on flat enamel surfaces of bovine anterior teeth, with free-running Er:YAG laser very short pulses (pulse length = 90-120 micros, repetition rate = 10 pulses per second). Four different output energies (100, 200, 300 and 400 mJ) were radiated on samples under distilled water from different distances (0.5, 0.75, 1, 1.25, 1.75 and 2.00 mm). The tooth slices were prepared with a cutting machine, and the surfaces of the ablated areas were measured with software under a light microscope. The average and standard deviation of all cut areas in different groups were reported. There was no significant difference when using a different pulse ablation speed (cm(3)/J) and a water-layer thickness between the tip and enamel surface of 0.5-1.25 mm with energy densities of 30-60 J/cm(2) (200-400 mJ). However, using an output energy of 15 J/cm(2) (100 mJ) and a thicker water layer than 1 mm, a linear ablation did not take place. This information led to a clearer view of the efficiency of Er:YAG laser in the conditions of this study. There are several hypotheses which describe a hydrokinetic effect of Er,Cr:YSGG. These basic studies could guide us to have a correct attitude regarding hydro-mechanical effects of water, although the wavelength of 2.78 microm has a better absorption in hydroxyl branch of water molecules. Therefore, our results do not directly interrupt with the series of investigations done with Er,Cr:YSGG. Water propagation and channel formation under water are investigated during the ablation of tooth enamel with the Er:YAG laser from different distances. Comparing the results of this study with the same research done with water/air spray concludes that the bubble formation and channel propagation in water with this wavelength leads to a more symmetric (linear) ablation process with cavity-preparation-recommended parameters.


Assuntos
Esmalte Dentário/efeitos da radiação , Terapia a Laser/instrumentação , Lasers de Estado Sólido , Água , Animais , Bovinos , Colagem Dentária , Dentina/efeitos da radiação , Terapia a Laser/métodos , Terapia com Luz de Baixa Intensidade , Modelos Animais
15.
Lasers Med Sci ; 23(1): 27-33, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17361391

RESUMO

It has been emphasized that one of the most valuable treatment objectives in dental practice is to afford the patient a pain-free treatment. By the evolution of the laser applications, the dental committee aimed to achieve this goal without analgesic drugs and painful methods. Orthodontic treatment is one of these concerns, that one of the major components of patient to reject this treatment is the pain accompanied during the different treatment phases. Another great concern of the patient is not to get through prolonged periods of treatment. The aim of this study is to evaluate the effect of the low-level (GaAlAs) diode laser (809 nm, 100 mW) on the canine retraction during an orthodontic movement and to assess pain level during this treatment. A group of 15 adult patients with age ranging from 14 to 23 years attended the orthodontic department at Dental School, Damascus University. The treatment plan for these patients included extraction of the upper and lower first premolars because there was not enough space for a complete alignment or presence of biprotrusion. For each patient, this diagnosis was based on a standard orthodontic documentation with photographs, model casts, cephalometric, panorama, and superior premolar periapical radiographies. The orthodontic treatment was initiated 14 days after the premolar extraction with a standard 18 slot edgewise brackets [Rocky Mountain Company (RMO)]. The canine retraction was accomplished by using prefabricated Ricketts springs (RMO), in both upper and lower jaws. The right side of the upper and lower jaw was chosen to be irradiated with the laser, whereas the left side was considered the control without laser irradiation. The laser was applied with 0-, 3-, 7-, and 14-day intervals. The retraction spring was reactivated on day 21 for all sides. The amount of canine retraction was measured at this stage with a digital electronic caliper (Myoto, Japan) and compared each side of the relative jaw (i.e., upper left canine with upper right canine and lower left canine with lower right canine). The pain level was prompted by a patient questionnaire. The velocity of canine movement was significantly greater in the lased group than in the control group. The pain intensity was also at lower level in the lased group than in the control group throughout the retraction period. Our findings suggest that low-level laser therapy can highly accelerate tooth movement during orthodontic treatment and can also effectively reduce pain level.


Assuntos
Terapia com Luz de Baixa Intensidade , Fechamento de Espaço Ortodôntico/instrumentação , Técnicas de Movimentação Dentária/instrumentação , Adolescente , Adulto , Feminino , Humanos , Masculino , Braquetes Ortodônticos , Fechamento de Espaço Ortodôntico/métodos , Medição da Dor , Estatísticas não Paramétricas , Técnicas de Movimentação Dentária/métodos
16.
Lasers Med Sci ; 22(4): 261-4, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17334676

RESUMO

The effects of low-level lasers on bone cellular activity, bone structures, bone healing, fibroblasts activity and inflammation process have already been investigated. Considering orthodontic tooth movement, which is a complicated inflammatory process involving simultaneous bone apposition and resorption, the aim of this controlled study is to investigate the quantitative effects of a pulsed 850 nm laser (Optodan) and a continuous 630 nm laser (KLO3) on the orthodontic tooth movement in rabbits. This experimental study was conducted on 18 male albino rabbits divided into three equal groups of control, Optodan and KLO3. In all the groups, NiTi-closed coil springs were used on the first mandibular molars with 4-oz tension. The control group was not irradiated by laser, but the teeth in the laser groups were irradiated 9 days according to the periodontal therapeutic protocols. After 16 days, samples were sacrificed. The distance between the distal surface of the first molar and the mesial surface of the second molar was measured with 0.05-mm accuracy. The data were subjected to the statistical tests of Kolmogrov Smirnov and variance analysis. The mean orthodontic tooth movements of the first mandibular molars were 1.7 +/- 0.16 mm in control group, 0.69 +/- 0.16 mm in Optodan group and 0.86 +/- 0.13 mm in KLO3 group. There were statistically significant difference between the control and the two other laser-irradiated groups (P < 0.001). The findings of the present study imply that the amounts of orthodontic tooth movement, after low-level laser therapy, are diminished. It could not be concluded that any low-level laser will reduce the speed of teeth movement in orthodontic treatments, and further studies with less or more energies may show different results.


Assuntos
Remodelação Óssea/efeitos da radiação , Terapia com Luz de Baixa Intensidade , Técnicas de Movimentação Dentária , Animais , Lasers , Masculino , Osteogênese/efeitos da radiação , Periodonto , Coelhos , Fatores de Tempo
17.
Lasers Med Sci ; 22(1): 21-4, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17115237

RESUMO

Dentin hypersensitivity (DH) is one of the most common complications that affect patients after periodontal therapy. So far, many investigators have successfully used different types of laser on DH treatment. The aim of this study was to evaluate the comparative effect of Nd:YAG laser and Er:YAG laser on human teeth desensitization. A group of nine patients with a total of 63 chronic hypersensitive teeth were selected. Each one of them should at least have three hypersensitive teeth. These teeth were randomly allocated into three groups. Group 1, Nd:YAG laser (1 W, 15 Hz, 60 s, two times); group 2, Er:YAG laser (100 mJ, 3 Hz, 60 s, two times); and group 3 serves as control group without any treatment. Assessment of pain was performed by a visual analysing scale (VAS) after stimulation of sensitive tooth by using the sharp tip of an explorer. This test was performed before treatment, immediately after that and at 1-, 3- and 6-month intervals after treatment by one blinded examiner. Analysis of VAS score between the three groups at the time of treatment did not show any significant difference (p = 0.506). However, by using repeated-measurement analysis of variance test, significant differences were seen in the three groups between before-treatment VAS score and after treatment (p < 0.0005). This statistically significant difference in the control group demonstrated a placebo effect. However, the effect of using Nd:YAG and Er:YAG lasers was stronger than this placebo effect, so that after removing the effect of the placebo, differences immediately after, 1, 3 and 6 months post treatment between all three groups still were statistically highly significant (p < 0.0005). Compared to the Er:YAG laser group, using Nd:YAG laser resulted in a significant reduction of VAS score at each follow-up examination (p < 0.0005). Although using Nd:YAG and Er:YAG laser in desensitization of hypersensitive teeth showed a placebo effect limited to a short time, results of this study demonstrated that both of these lasers have an acceptable therapeutic effect. The observed effects seemed to last for at least 6 months. It was concluded that Nd:YAG laser is more effective than Er:YAG laser in reduction of patients' pain.


Assuntos
Sensibilidade da Dentina/terapia , Terapia a Laser , Análise de Variância , Érbio , Feminino , Humanos , Masculino , Neodímio , Medição da Dor , Resultado do Tratamento
19.
Lasers Med Sci ; 20(2): 99-103, 2005 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16007476

RESUMO

The thermal rise threshold of an 810-nm semi-conductor diode laser on the root surface when used in root canals in vitro for laser assisted root canal treatment is investigated in this study. A total of 50 human single-rooted extracted teeth were included. For this study, the canals were enlarged up to an apical size of ISO#50 file. Laser irradiation was performed with six different settings. Specimens were irradiated at 0.6-1 W output power at the distal end of the fiber and about 1-1.5 W output power in the continuous mode (CW) as two groups. In the third group, 0.6-1 W output power, 10 ms pulse length (PL) and 10 ms interval duration (ID) were selected. In three other groups 1-1.5 W output power were used with different PL and ID as following: PL 10 and ID 10 ms, PL 10 and ID 20 ms and PL 20 and ID 20 ms. The total irradiation time was from 5 to 20 s per canal with a 200 mum in diameter and 25 mm long tip. After laser treatment, the temperature changes at the outer root surface were registered by means of NiCr-Ni measuring sensors and a T 202 thermometer. The safe temperature threshold for applying this diode laser in root canal is considered as 7 degrees C increase. To avoid increasing the temperature changes at the outer root surface related to this threshold, following total irradiation times were found: 0.6-1 W output power (10 ms PL/10 ms ID): 20 s (s), 1-1.5 W output power (10 ms/10 ms and 20 ms/20 ms): 15 s, 0.6-1 W output power CW and 1-1.5 W output power (20 ms PL/10 ms ID): 10 s and 1-1.5 W output power CW: 5 s. In the first three groups, 5 s irradiation and 5 s rest period avoided a temperature increase above the threshold of 7 degrees C).


Assuntos
Temperatura Corporal/efeitos da radiação , Lasers , Raiz Dentária/efeitos da radiação , Endodontia , Humanos , Termômetros , Raiz Dentária/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...